Next: 11 Frequency calculations Up: quickstart Previous: 9 Density functional calculations


10 Geometry optimization

Geometry optimizations are invoked by the optg input directive, which must follow the input of the method for which the optimization is to be performed. For instance, optimization of the geometry for formaldehyde at the MP2 level is performed with the following input

***,formaldehyde
print,basis,orbitals   !this is optional: print the basis set and the
                       !occupied orbitals
geometry               !define the nuclear coordinates
ang
C
O  , C , rco
H1 , C , rch , O , hco
H2 , C , rch , O , hco , H1 , 180
end

rco=1.182 Ang
rch=1.102 Ang
hco=122.1789 Degree

basis=vdz              !Select basis set
hf                     !Perform HF calculation
mp2                    !Perform MP2 calculation
optg                   !Optimize geometry for MP2

Optimizations use analytical energy gradients if available; otherwise the gradients are computed by finite differences. Presently, analytical energy gradients are available for the following methods.

hf
Closed and open-shell spin restricted Hartree-Fock (RHF)
uhf
Spin-unrestricted Hartree-Fock (UHF).
ks
Spin-restricted closed and open-shell Kohn-Sham calculations.
uks
Spin-unrestricted Kohn-Sham calculations.
mcscf
MCSCF and CASSCF, including state-averaged calculations
mp2
closed-shell MP2
lmp2
closed-shell local MP2
qcisd
closed-shell quadratic configuration interaction

Various options are available for modifying the convergence thresholds and the optimization method. For details see the reference manual.



molpro@molpro.net