Next: 9.8 Do loops Up: 9.7 Procedures Previous: 9.7.2 MP2 geometry optimization

9.7.3 DFT frequency calculation

The following input performs a DFT/B3LYP geometry optimization and frequency calculation for water:

Input: h2o_freqdft.com

Output: h2o_freqdft.out

The results are

 RESULTS FOR BASIS=6-31G** 

 METHOD          STATE     S       ENERGY    DIPX  DIPY     DIPZ
 FREQ[KS/B3LYP]    1.1   0.0   -76.38101813   0.0   0.0   0.80039692
 ZPE               1.1   0.0     0.02697203   0.0   0.0   0.80039692
 E+ZPE             1.1   0.0   -76.35404610   0.0   0.0   0.80039692
 HTOTAL            1.1   0.0   -76.35023712   0.0   0.0   0.80039692
 GTOTAL            1.1   0.0   -76.37236272   0.0   0.0   0.80039692

The frequencies, intensities and further details can be found in the output file.


molpro@molpro.net
Oct 10, 2007